fireproof coating for industrial use
2.Performance: Multi-substrate compatible, fire-resistant, weather-resistant, durable, eco-friendly;
3.Application: Overall fire protection of civil, commercial and industrial buildings, including walls, beams and columns;
4.Construction: Spraying or brushing, simple operation, suitable for large-scale building construction;
5.Parameter: Fire resistance ≥1.8h, compliant with international building fire standards, service life ≥12 years.
6. +5~40°C; RH≤85%; substrate ≥3°C above dew point.
7. Indoor no UV/weather resistance; outdoor needs UV/weather finish.
8. Indoor protected use; outdoor >5y requires UV/weather system.
9. Store 5–45°C dry; shelf 12m water/solvent, 6m cement.
10. Water/cement non-hazardous; solvent flammable UN1263 Class 3.
11. VOC water≤120g/L; solvent≤650g/L.
- Product Description
Fireproof Coating for Industrial Use: Professional Fire Protection Solutions
The right fireproof coating for industrial use makes all the difference when it comes to protecting buildings that are used for work. We at Henan Banggu Fire Technology Co., Ltd. have been making coatings for more than 30 years. Our safe paints for industry are resistant to fire for 1.8 hours and last for 12 years. Our multi-substrate compatible systems meet international building fire standards and are cost-effective and easy to use, whether you need to protect steel structures, concrete walls or wooden parts in factories, stores or production sites.
Why Choose Our Industrial Fireproof Coating?
Proven Fire Protection Performance
Your business goods should be well taken care of. When our coating comes into contact with fire, it quickly expands, creating a thick layer of carbonised heat insulation that slows the rate at which the base heats up. It works reliably and meets GB 8624-2012 Class A standards. Standards for things that don't catch fire and international fire safety rules.
Built for Industrial Environments
Tougher options are needed in industrial settings. The problem is solved by our product:
- Compatible with multiple substrates: works on steel beams, concrete walls, and wooden buildings
- formulated to withstand the weather: indoor and outdoor uses are covered
- Surface drying takes less than 4 hours, and hard drying takes less than 24 hours.
- Strong defence: 12 years or more of use in the right conditions
Clean and Safe for Your Workplace
For fire safety, you shouldn't put worker safety at risk. Our low-VOC blend (100g/L) doesn't have any gaseous substances that are bad for you. It's ISO 14001 approved, which means that your building meets strict environmental standards and keeps your team safe.
Technical Specifications
| Parameter | Value |
|---|---|
| Product Appearance | Uniform viscous liquid, no caking, no delamination |
| Surface Drying Time | ≤4h |
| Hard Drying Time | ≤24h |
| Fire Resistance Duration | ≥1.8h |
| Combustion Performance | GB 8624-2012 Class A Non-combustible |
| VOC Content | ≤100g/L |
| Service Life | ≥12 years |
| Application Temperature | +5~40°C; RH≤85% |
| Storage Temperature | 5–45°C dry conditions |
| Shelf Life | 12 months (water/solvent base), 6 months (cement base) |
Application Scenarios
Our fireproof coating serves diverse industrial applications:
- Manufacturing plants and production facilities
- Warehouses and distribution centers
- Industrial steel structures and frameworks
- Commercial buildings with industrial zones
- Tunnel linings and cable protection systems
Simple Application Process
You don't need specialized equipment for application. Our coating works with standard spraying or brushing methods:
- Surface preparation: Clean and treat substrate (derust for steel, remove dust and grease)
- Primer application: Apply compatible primer for better adhesion
- Coating application: Spray or brush multiple coats to required thickness
- Curing: Allow proper drying time based on environmental conditions
The straightforward process makes large-scale industrial construction projects manageable and cost-effective.

Comprehensive Support Throughout Your Project
Before You Order
We help you select the right solution. Our technical team provides free consultation, product selection guidance, and documentation support including test reports and certification files.
During Installation
You get 24/7 remote construction guidance. We supply standardized installation manuals and answer technical questions as they arise.
After Completion
We assist with acceptance documentation, coordinate fire safety inspections, and provide remote troubleshooting. Our lifetime technical support ensures your fireproof coating for industrial use continues protecting your investment.
Backed by Certifications You Can Trust
Our quality management systems meet international standards:
- ISO 9001 Quality Management System
- ISO 14001 Environmental Management System
- ISO 45001 Occupational Health and Safety Management
- CE Certification for global market access
These certifications demonstrate our commitment to consistent quality and reliable performance.
FAQ
Q1: What exactly is fireproof coating, and what is its core function?

A: A fireproof coating is useful and fire retardant. It forms a heat-insulating and oxygen-isolating fire protection layer on building surfaces, steel structures, and timber. It delays substrate igniting, increases evacuation time, and decreases fire spread and property damage.
Q2: How are fireproof coating fire ratings classified?
A: Fire ratings vary by standard. Domestically, GB 14907-2018 defines steel building fireproof coatings as NCB (indoor ultra-thin), NB, and NH, with fire resistance from 0.5 to 3 hours. The international EN 13501-1 employs grades A1, A2, B, C, D, E, and F. Higher ratings offer longer fire resistance and stronger high-risk protection.
Q3: Is building difficult? Are professional teams necessary?
A: Construction requires substrate treatment, primer application, fireproof coating application, and curing. Basic construction workers can tackle simple jobs. Professional construction teams assure excellence for huge industrial projects with high fire ratings.
Q4: What's the validity period? Should I reapply after expiration?

A: Environmental exposure shortens outdoor coatings to 3-5 years and inside coatings to 5-8 years. Check coating after expiry. Cracks, peeling, or chalking need cleaning and reapplication. Local repairs might increase service life if the coating is intact.
Q5: Can fireproof coating prevent all fires?
A: Fireproof coating only slows fire propagation, not extinguishes or prevents fires. It slows substrate burning after a fire, allowing escape and rescue and reducing losses. Not absolute prevention, but supplemental protection.
Contact Us
Ready to protect your industrial facility with fireproof coating for industrial use? Email us at banggu@bgfireproof.com for product information, technical support, or custom quotations today.