banner

heat resistant fireproof coating

1.Product type: Heat-resistant integrated fireproof coating;
2.Performance: Good heat insulation, heat-resistant, non-flammable, strong adhesion, durable;
3.Application: Thermal equipment, pipelines, engine parts, high-temperature workshops;
4.Construction: Spraying or brushing, fast drying, adaptable to continuous high-temperature conditions;
5.Parameter: Temperature resistance up to 800℃, heat transfer reduction rate ≥50%, fire resistance ≥2h.
6. Construction +5~40°C; RH≤85%; substrate ≥3°C above dew point.
7. Indoor coatings lack UV/weather resistance; outdoor needs UV/weather protection.
8. Indoor use only; outdoor exposure >5 years needs UV/weather system.
9. Store 5–45°C, dry; shelf life: water/solvent 12m, cement 6m.
10. Water/cement non-hazardous; solvent flammable (>60°C) UN1263 Class 3.
11. VOC water≤120g/L; solvent≤650g/L compliant.
Send Inquiry Download
  • Product Description

Heat Resistant Fireproof Coating – Professional Fire Protection Solutions

Our heat resistant fireproof coating works great in industrial and business settings. The advanced coating, made by Henan Banggu Fire Technology Co., Ltd., can withstand temperatures of up to 800℃ and cuts heat flow by up to 50%. Our product has GB 8624-2012 Class A non-combustible certification and fire resistance of at least two hours, protecting thermal equipment, pipes, engine parts, and high-temperature workshops. Over 30 years of coating experience and ISO 9001, ISO 14001, and ISO 45001 certifications support enterprise-level fire prevention that satisfies international safety standards.

Why Choose Our Heat Resistant Fireproof Coating?

You require a coating that works in harsh circumstances. Innovative technology and tested dependability come together in our product.

Better Resistance to Heat

Your equipment is constantly exposed to hot temperatures. A temperature of 800℃ doesn't affect the structure of this layer. When heat is applied, a thick carbonised heat-insulating layer forms quickly, keeping your valuables safe.

Quick to apply and dry

Having enough time to work on projects is important. You can either spray or brush this layer on. It takes 4 hours for the top to dry, and 24 hours for the whole thing to dry. In real life, this means shorter building times and finishing projects faster.

Excellent Adhesion and Durability

What you want is long-lasting safety. Our fireproof coating that can withstand heat sticks well to many different types of surfaces. This thing stays strong and effective over time, even though it is always exposed to high temperatures.

Environmentally Safe

Our main goal is to keep your job safe. This covering follows strict rules for the environment because it has less than 100g/L of VOC. It's safe for both users and building workers to use because it doesn't hurt anyone.

Technical Specifications

ParameterSpecification
Product AppearanceUniform viscous liquid, no caking, no delamination
Surface Drying Time≤4h
Hard Drying Time≤24h
Temperature ResistanceUp to 800℃
Heat Transfer Reduction≥50%
Fire Resistance≥2h
Combustion Performance GradeGB 8624-2012 Class A Non-combustible
VOC Content≤100g/L
Construction Temperature+5~40°C
Relative HumidityRH≤85%
Shelf LifeWater-based: 12 months; Solvent-based: 12 months; Cement-based: 6 months
Storage Temperature5–45°C, dry conditions

Key Applications

Thermal Equipment Protection

Your high-temperature machinery needs reliable coating. This product protects boilers, furnaces, and industrial ovens from fire hazards.

Pipeline Systems

You can't afford pipeline failures. Our coating shields exhaust systems, flue pipes, and industrial ducts operating under extreme heat.

Engine Components

Vehicle and machinery engines require specialized protection. This coating withstands engine compartment temperatures while preventing fire spread.

High-Temperature Workshops

Your facility demands comprehensive fire safety. Apply this heat resistant fireproof coating to walls, steel structures, and equipment in foundries, smelting plants, and manufacturing facilities.

Application scenario

Complete Technical Support

You receive more than just a product. Our team provides comprehensive assistance throughout your project.

Pre-Sales Consultation

We help you select the right solution for your specific needs. You get free technical documentation, test reports, and certification documents.

During Construction

Access 24/7 remote guidance when you need it. Our standardized installation manuals ensure proper application.

After-Sales Service

We support your project through acceptance documentation and fire safety inspection coordination. Remote troubleshooting keeps your operations running smoothly.

Industrial coating

OEM and ODM Services

Your brand deserves customized solutions. We offer flexible manufacturing options:

ODM Services: We handle product design, formulation development, and prototyping. You customize logos, packaging, and colors for your market.

OEM Services: Provide your specifications, and we manufacture to your exact requirements while maintaining strict quality control.

FAQ

Q1: What is fireproof coating and why is it used?

A: Functional fireproof coating is fire retardant. Once applied to buildings, steel structures, and wood, it forms a heat-insulating and oxygen-isolating protective layer during a fire. It reduces substrate ignition and damage, giving workers and fire rescue time.

Q2: How are fireproof coating fire ratings classified, and what happens between grades?

A: NCB, NB, and NH steel building fireproof coatings have fire resistance values of 0.5 to 3 hours. En 13501-1 grades fire performance A1, A2, B, C, D, E, and F internationally. Better heat insulation and longer fire resistance with higher grades.

Q3: Is the thickness of the fireproof coating application required?

A: Fire rating, coating type, and substrate type indicate requirements. Thicker coatings require 10-50mm for 2-3 hours fire resistance, whereas ultra-thin coatings require 0.3-0.8mm for 0.5-1 hour. Too thin won't satisfy fire protection requirements; too thick may crack and cost more.​​​​​​​

Q4: Can fireproof coating be used with other coatings?

A: Yes, but order counts. Put on the product and let it dry. Apply ornamental latex or fluorocarbon paint. Chemical reactions can be avoided by coating compatibility. We advise small-area testing before mass application.

Q5: Must exported fireproof coatings fulfil international standards?

A: Absolutely. Coatings exported must fulfil country norms. US exports need UL certification, European exports need EN 13501, and Southeast Asian markets have local requirements. Products must be tested, quality certified, and origin-certified for customs clearance.

heat resistant fireproof coating

Quality Certifications You Can Trust

Strict international requirements are met by our manufacturing procedures:

Certifications for ISO 9001 Quality Management Systems, ISO 14001 Environmental Management Systems, and ISO 45001 Occupational Health and Safety Management Systems

CE Certification compliance with GB 14907-2018 for fireproof coating of steel structures

These certificates guarantee that you will consistently obtain items that satisfy international legal criteria.

Contact Us

Ready to protect your assets with heat resistant fireproof coating? Contact our technical team for product selection guidance and customized solutions. Email us at banggu@bgfireproof.com for expert consultation.

Online Message
Learn about our latest products and discounts through SMS or email