exterior fireproof coating
2.Performance: Weather-resistant, UV-resistant, rainproof, anti-aging, strong fire resistance;
3.Application: Outdoor walls, roofs, steel structures, bridges and public facilities;
4.Construction: Spraying or rolling, adaptable to outdoor temperature changes;
5.Parameter: Fire resistance ≥1.5h, weather resistance grade 1, service life ≥8 years.
6. +5~40°C; RH≤85%; substrate ≥3°C above dew point to prevent moisture.
7. Indoor not UV/weather resistant; outdoor must use UV/weather layer.
8. Indoor use only; outdoor exposure >5y needs UV/weather system.
9. Store dry 5–45°C; shelf life water/solvent 12m, cement 6m.
10. Water/cement non-hazardous; solvent flammable UN1263 Class 3.
11. VOC water≤120g/L; solvent≤650g/L compliant.
- Product Description
Exterior Fireproof Coating for Outdoor Steel & Building Protection
To keep outdoor buildings safe from fire risks, you need more than just regular protection. You need an exterior fireproof coating that is made to work in real life. The outdoor fireproof coating from Henan Banggu Fire Technology is resistant to fire for 1.5 hours, works well in grade 1 weather, and lasts for more than 8 years. With over 30 years of experience making coatings and production that is ISO 9001 certified, our answer protects steel structures, bridges, roofs, and public buildings in all kinds of weather by blocking UV rays, keeping them dry, and slowing down the ageing process.

Why Outdoor Fire Protection Demands Specialized Solutions?
The things you put outside have special needs that home coatings just can't handle.
Rain and UV rays. Changes in temperature. Changes in humidity.
Standard fire-resistant goods fail within months of being put through these tests. Because of this, our product has parts that can withstand the weather and were designed to work outside. Formulations made for indoor use only focus on flame resistance. Our outdoor choice keeps its fire resistance while also being resistant to damage from the weather.
As a result? Strong protection that doesn't crack, peel, or stop working after one season.
Technical Specifications That Matter
| Parameter | Specification |
|---|---|
| Product Appearance | Uniform viscous liquid, no caking, no delamination |
| Surface Drying Time | ≤4h |
| Hard Drying Time | ≤24h |
| Combustion Performance | GB 8624-2012 Class A Non-combustible |
| VOC Content | ≤100g/L |
| Fire Resistance | ≥1.5h |
| Weather Resistance | Grade 1 |
| Service Life | ≥8 years |
| Application Temperature | +5~40°C; RH≤85% |
| Shelf Life | Water-based: 12 months; Cement-based: 6 months |
Four Key Advantages for Your Projects
1. Fire Resistance Performance
When the flames hit, our coating quickly expands into a dense carbonised heat insulating layer. This barrier inhibits the heating of the substrate, safeguarding the steel beams, concrete surfaces and structural parts. You’ll gain consistent adherence to international fire safety codes—essential for export projects and multi-country engineering work.
2. Built to Last Outdoors
Normal coatings get destroyed by UV deterioration after 1-2 years. Our recipe also contains specialised UV stabilisers and anti-aging chemicals that preserve integrity for over 8 years. Whether your construction is subject to desert sun or coastal humidity, protection is universal.
3. Chemistry with an environmental conscience
Our exterior fireproof coating complies with stringent global environmental laws with VOC concentration of 100g/L and ISO 14001 Environmental Management certification. Thanks to its non-toxic recipe, it’s safe for the applicators and the people who occupy the building, no dangerous volatile compounds, no trade-offs.
4. Quality & Compliance Certification
We are ISO 9001, ISO 14001 and ISO 45001 certified and CE marked for European markets. Our solutions meet the Middle Eastern and Southeast Asian regulatory requirements, giving you paperwork confidence for cross-border projects.
Application Versatility
This coating adapts to multiple outdoor scenarios:
- Steel structures (warehouses, factories, bridges)
- Building exteriors (walls, columns, facades)
- Roofing systems (metal and concrete)
- Public infrastructure (tunnels, stations, facilities)
- Petrochemical installations (tanks, pipelines)
Application methods include spraying and rolling, accommodating various construction conditions and substrate geometries.
Professional Support Throughout Your Project
We provide comprehensive technical assistance across three phases:
Before Purchase: Free product selection consultation, test reports, and certification documents to support your bidding and approval processes.
During Application: Remote construction guidance, standardized installation manuals, and 24/7 technical support to ensure proper coating thickness and uniformity.
After Completion: Acceptance documentation assistance, fire inspection coordination, and batch traceability for quality management.
For complex projects, our senior engineers offer tailored construction solutions and fire resistance calculation verification.

FAQ
Q: How is product distinct from indoor products?
A: Weatherproofness matters. The UV blockers, moisture barriers, and anti-corrosion ingredients in our outdoor recipe survive rain, sun, and temperature extremes. Without these components, indoor coatings will fracture and peel within months of environmental stress.
Q: How long does the coating dry, and what precautions are needed?
A: Surface drying takes 4 hours and hard drying takes 24 hours at 25℃ and 50% humidity. Avoid rain, sunshine, and physical impact when curing. Avoid open flames and ventilate. Avoid dusting moist surfaces.
Q: Is it possible to decorate the fireproof layer?
A: Yes. Latex or fluorocarbon finishes can be applied once the fireproof coating hardens. Always do a small-area compatibility test to prevent chemical interactions that could damage fire performance.
Q: How thick must coatings be for different fire ratings?
A: Fire resistance and substrate type determine thickness. Extremely thin applications (0.3-0.8mm) provide 0.5-1 hour protection. Steel constructions need adequate thickness calculation based on section factor and exposure conditions for ≥1.5 hour resistance. Our engineers can make project-specific suggestions.
Q: How can I prolong the coating's 8-year lifespan?
A: An annual visual inspection for cracks, peeling, or chalking. Softly scrub surfaces to eliminate dirt. Localised repairs for minimal damage are immediate. Avoid chemicals and mechanical damage. In hostile coastal or industrial locations, biennial examinations can detect damage early.

Partner With Proven Expertise
Henan Banggu Fire Technology serves engineering contractors, distributors, and commercial consumers worldwide since 2019. Our location in Changyuan City, China's "Capital of Anti-Corrosion"—has key highway and railway access for rapid project delivery.
We customise OEM and ODM products to your branding, packaging, and technical needs. Our quality control is tight whether you need private label items or formula contract manufacturing.
Contact Us
Ready to protect your outdoor structures with exterior fireproof coating? Contact our technical team at banggu@bgfireproof.com for product specifications, samples, and project consultation.
YOU MAY LIKE
VIEW MOREfireproof coating for industrial use
VIEW MOREfireproof coating for concrete
VIEW MOREfireproof coating for walls
VIEW MOREfireproof coating for buildings
VIEW MOREsolvent-based fireproof coating
VIEW MOREhigh temperature fireproof coating
VIEW MOREheat resistant fireproof coating
VIEW MOREacrylic fireproof coating