fireproof coating for walls
2.Performance: Good adhesion to concrete, heat-insulating, anti-cracking, fire-resistant, weather-resistant;
3.Application: Concrete walls, floors, beams, columns in civil buildings, tunnels and industrial factories;
4.Construction: Spraying or troweling, easy to level, adaptable to concrete surface defects;
5.Parameter: Fire resistance ≥2.5h, compression strength ≥30MPa, anti-cracking, service life ≥10 years.
6. +5~40°C; RH≤85%; substrate ≥3°C above dew point to prevent moisture.
7. Indoor not UV/weather resistant; outdoor must use UV/weather layer.
8. Indoor use only; outdoor exposure >5y needs UV/weather system.
9. Store dry 5–45°C; shelf life water/solvent 12m, cement 6m.
10. Water/cement non-hazardous; solvent flammable UN1263 Class 3.
11. VOC water≤120g/L; solvent≤650g/L compliant.
- Product Description
Fireproof Coating for Walls: Professional Fire Protection Solutions
Concrete walls in commercial buildings, tunnels, and industrial facilities need certified fire protection, not just paint. This fireproof coating for walls offers enterprise-grade performance with a ≥2.5 hour fire resistance rating and compression strength surpassing 30MPa. Henan Banggu Fire Technology Co., Ltd. developed this concrete-specific coating using advanced formulation technology and 30 years of manufacturing experience. It sticks very well, doesn't crack, and lasts for more than 10 years. Our coating is better than CE, ISO 9001, ISO 14001, and ISO 45001 standards for hospital hallways, subway stations, and industrial floors because it keeps heat in and has a smooth, professional finish.
Why Choose Our Concrete Wall Fire Protection System?
Proven Fire Resistance Performance
Your walls undergo tremendous circumstances during fires. After flame exposure, our coating generates a dense carbonised heat-insulating layer that greatly slows concrete substrate temperature rise. The GB 8624-2012 Class A non-combustible rating gives residents essential evacuation time.
Easy Application & Fast Project Completion
On building sites, time matters. The products dries fast, with a surface drying time of 4 hours and a hard drying time of 24 hours. You may spray or trowel it on, and it responds to surface flaws. This cuts building time and labour costs.
Safe & Environmentally Compliant
Nonnegotiable: health and safety. At ≤100g/L VOC concentration, our coating is free of hazardous volatile chemicals. Schools, hospitals, and homes may use it because it's odourless, non-toxic, and harmless. ISO 14001 certifies our environmental responsibilities.
Versatile Application Range
From subterranean parking garages to industrial warehouses, our coating protects concrete walls, floors, beams, and columns:
- Residential/commercial civil structures
- Transportation tunnels/underpasses
- Manufacturing plants
- Infrastructure projects public
Technical Parameters
| Parameter | Specification |
|---|---|
| Product Appearance | Uniform viscous liquid, no caking, no delamination |
| Surface Drying Time | ≤4h |
| Hard Drying Time | ≤24h |
| Combustion Performance | GB 8624-2012 Class A Non-combustible |
| VOC Content | ≤100g/L |
| Fire Resistance | ≥2.5h |
| Compression Strength | ≥30MPa |
| Service Life | ≥10 years |
| Application Temperature | +5~40°C |
| Relative Humidity | RH≤85% |
Construction Guidelines for Optimal Results
Indoor Applications
Our fireproof coating for walls performs best in controlled indoor environments. Ensure substrate temperature stays ≥3°C above dew point to prevent moisture-related issues. The coating is not UV or weather resistant, so reserve it for interior concrete surfaces.
Outdoor Considerations
If it will be outside for more than 5 years, you need to use a finish method that is resistant to UV light and weather. This protected layer keeps the fire resistance qualities while stopping damage from sunlight and rain.

Storage Requirements
Keep the containers dry between 5°C and 45°C. Formulations that are water- or solvent-based can be stored for 12 months, while forms that are based on cement can be stored for 6 months. Types that contain water and cement are not dangerous, but types that contain solvents are flammable (UN1263 Class 3).
Why Engineering Contractors Trust Banggu?
30+ Years of Coating Expertise
We inherited decades of manufacturing knowledge from Henan Tiantan Anti-corrosion Co., Ltd. This deep technical foundation allows us to balance fire performance with practical construction needs. You're not buying from a startup—you're partnering with proven industry specialists.
Complete Certification Portfolio
International projects demand documentation. We provide CE certification, ISO 9001 quality management, and compliance documentation for Middle East and Southeast Asian markets. Our products meet the regulatory requirements your projects face globally.
Flexible Customization Options
Every project has specifications. We offer OEM manufacturing to your formulas and ODM development with custom branding, colors, and packaging. Whether you need 100 drums or 10,000, we scale production to match your timeline.
End-to-End Technical Support
You're never alone during project execution:
- Pre-sales: Free product selection consultation and technical documentation
- During construction: 24/7 remote guidance and standardized installation manuals
- After completion: Acceptance documentation and fire safety inspection coordination
Our senior engineers assist with construction solutions, fire resistance calculations, and regulatory approvals for complex applications.
FAQ
Q1: What substrates can fireproof coating protect?

A: Our coating clings well to concrete walls, floors, beams, and columns. Civil, tunnel, and industrial constructions can use it. However, fusible polymer materials like plastic and rubber require flame retardant treatments.
Q2: How long does coating cure?
A: Surfaces dry in 4 hours at 25℃ and 50% humidity. Drying hard takes 24 hours. Rain, direct sunshine, and physical impact should be avoided at this time. Avoid open flames and ventilate.
Q3: What's the service life and when to reapply?
A: Indoor applications last 5-8 years with good care. Environmental factors may require 3-5-year replacement of outdoor installations. Check for cracks, peels and chalking. If the coating is intact, minor repairs may work; otherwise, reapplication provides protection.
Q4: is this coating safe during and after application?

A: Yes. Our recipe is environmentally friendly and free of volatile chemicals. Construction workers should wear masks, gloves, and goggles and ventilate. Fully cured coating is safe for inhabited environments.
Q5: Is decorative paint allowed over fireproofing?
A: Absolutely. You can add latex paint or fluorocarbon coatings once the products has dried fully. Start with a tiny area to guarantee adherence and no chemical reactions. This method protects against fire and looks good.
Contact Us
Ready to add fireproof coating for walls to your project to improve fire safety? Customised product selection and technical documentation help are free from our staff.
Email: banggu@bgfireproof.com.
YOU MAY LIKE
VIEW MOREfireproof coating for industrial use
VIEW MOREfireproof coating for construction
VIEW MOREdurable fireproof coating
VIEW MOREnon-toxic fireproof coating
VIEW MOREsolvent-based fireproof coating
VIEW MOREhigh temperature fireproof coating
VIEW MOREpolyurethane fireproof coating
VIEW MOREwater-based fireproof coating