banner

Flame retardant coating for cable

1.Product type: Flame retardant coating for cable surface protection;
2.Performance: Rapid flame inhibition, good flame retardancy, anti-corrosion, flexible film, strong adhesion, low-odor;
3.Application: Indoor and outdoor cables, including power cables, communication cables and control cables;
4.Construction: Spraying, fast drying, thin film, does not affect cable flexibility and transmission performance;
5.Parameter: Fire resistance ≥1.5h, flame-retardant grade A, temperature resistance up to 1000℃, VOC content ≤25g/L.
6. Temp +5~40°C; RH≤85%; substrate ≥3°C above dew point.
7. Indoor not UV/weather resistant; outdoor requires UV/weather coat.
8. Indoor protected use; outdoor >5y needs UV/weather system.
9. Store 5–45°C dry/vent; shelf: 12m water/solvent, 6m cement.
10. Water/cement non-hazardous; solvent (>60°C) flammable UN1263.
11. VOC: water≤120g/L; solvent≤650g/L compliant.
Send Inquiry Download
  • Product Description

Flame Retardant Coating for Cable: Enterprise-Grade Fire Protection Solution

When you need to protect important electrical systems, you need a method that has been shown to work before. Henan Banggu's Flame retardant coating for cable provides high-level fire safety and is backed by more than 30 years of experience making coatings. Our finish can withstand fires for at least 90 minutes, is flame safe grade FV-0, and can handle temperatures up to 1000℃. With a VOC content of 25g/L and a flame spread ratio of 25, this low-odor, bendable film solution puts out flames quickly while still sticking well. Our coating makes sure that your installations meet international fire safety standards, whether you're protecting power lines, data cables, or control cables inside or outside.

Why Choose Our Cable Fire Protection Coating?

Every day, you have to deal with problems keeping wire lines safe from fire. These issues are directly dealt with by our layer.

When the recipe is put near fire, it forms a thick layer of carbonised insulation. This barrier really slows down the flow of heat to the insulation around the cables. This stops short circuits and fires from spreading along the cable runs.

Reliable performance is needed for your projects. Even though wires bend during normal use, our coating won't crack or flake because it stays flexible after it cures. With a film thickness of only 0.5–1 mm, you won't have to give up any gearbox speed or wire flexibility.

Your business cares about being environmentally friendly. This flame-resistant covering for cables has a non-toxic recipe and low VOC emissions. It meets the standards of the ISO 14001 Environmental Management System, so it can be used both indoors and outdoors without hurting people or the environment.

Technical Specifications

PropertySpecification
AppearanceBlack/grey viscous liquid, uniform with no sediment
Flexibility≤1 mm, no cracks
Oil ResistanceNo corrosion or flaking after 36 hours
Corrosion ResistanceResistant to acids, alkalis and salt spray
Flame Retardant GradeFV-0 grade
Fire Resistance Time≥90 minutes
Flame Spread Ratio≤25
Applicable ScenePower cables, telecommunications cables, cable trays
Construction Temperature0–40 °C
Coating Thickness0.5–1 mm
Drying MethodAir-dry at room temperature
Insulation PropertyGood; does not affect the cable's electrical conductivity
Storage ConditionStore in a cool, dry place away from sources of ignition

Application Scenarios

Your cable protection needs vary by project type. Our coating adapts to diverse environments:

Commercial Buildings: Fire safety for vertical cable shafts and distribution systems is important in shopping malls, hotels, hospitals, and office buildings.

Industrial Facilities: Power plants and substations gain from the coating's ability to withstand harsh conditions and protect the power source.

In order to keep people safe, subways and tubes need coatings that stop flames from spreading in small areas where time is of the essence for getting out.

Flame retardant coating for cable

Telecommunications: Installations of communication cables need to be protected in a way that doesn't affect the signal transfer but also keeps people safe in case of fire.

The coating does a great job of keeping out fires all over your system, protecting both wires and cable trays.

How to Apply the Coating?

Application is straightforward. You can use spraying, brushing, or rolling methods depending on your project requirements.

Ensure the ambient temperature stays between 5–40°C during application. Relative humidity should remain ≤85%, and the substrate temperature must be ≥3°C above the dew point.

Apply 2–3 coats to achieve the desired thickness. The surface dries in 1–2 hours, with full cure completed within 24 hours. Wait at least 4 hours between coats.

For outdoor applications requiring long-term exposure (>5 years), combine this flame retardant coating for cable with a UV/weather-resistant topcoat to ensure lasting protection.

Quality Certifications You Can Trust

We hold comprehensive international certifications that demonstrate our commitment to quality:

  • ISO 9001 Quality Management System Certification
  • ISO 14001 Environmental Management System Certification
  • ISO 45001 Occupational Health and Safety Management System Certification
  • CE Certification

Our products comply with GB 28374-2012 "Fire-Retardant Coating for Cables" national standards. Complete test reports and certificates accompany every shipment, ensuring your projects pass fire safety inspections without complications.

Comprehensive Technical Support

Your success matters to us. We provide support throughout your project lifecycle:

Flame retardant coating for cable

Before Purchase: Our technical consultants offer free product selection guidance based on your specific cable types and fire protection requirements. We supply all necessary technical documentation for project approvals.

During Installation: Access 24/7 remote construction guidance and standardized installation manuals. Our team helps you optimize application techniques for efficient project completion.

After Completion: We assist with acceptance documentation and fire safety inspection coordination. Lifetime remote technical support ensures you have expert advice whenever questions arise.

Storage and Handling

Store the coating at 5–45°C in a dry, ventilated location. The shelf life is 12 months for water-based and solvent-based formulas, and 6 months for cement-based versions.

Water-based and cement-based products are non-hazardous for transportation. Solvent-based products (>60°C flash point) are classified as flammable UN1263 and require appropriate shipping precautions.

FAQ

Q: What is cable fireproof coating used for?

A: It covers cables, trays, and ditches. It forms a thermal barrier that inhibits wires from sparking and flame spread when exposed to fire, guaranteeing emergency power and lights.

Q: Which criteria does it meet?

A: Our coating meets GB 28374-2012 "Fire-Retardant Coating for Cables" standard. Official test reports for fire safety inspections are included.

Flame retardant coating for cable

Q: Is it water-based or solvent-based?

A: Water-based, non-toxic, low-odor, eco-friendly, safe to apply, and non-flammable, the mainstream variety is appropriate for occupied buildings.

Q: Does it resist voltage? Is cable insulation affected?

A: Non-conductive, good insulating coating. After drying, it doesn't alter cable insulation, assuring safety and dependability.

Q: Can it pass fire safety inspection?

A: Yes. Complete paperwork (test reports + compliance certifications) meets national norms. It passes fire safety assessments when used properly.

Contact Us

Ready to protect your cable installations with Flame retardant coating for cable? Contact our technical team at banggu@bgfireproof.com for product specifications and project consultation.

Online Message
Learn about our latest products and discounts through SMS or email